NOMA®WOOL ALU / CLIMATUBE® WOOL 1m rock wool aluminum-coated
Breakdown of dimensions: Example: 15-20mm-> 15 mm pipe diameter x 20 mm insulation thickness
NOMA®WOOL ALU (CLIMATUBE® WOOL) rock wool insulation shells with surface coating of grid-reinforced aluminum foil.
The insulation shells are slit on one side and have a self-adhesive, overlapping adhesive strip for the easiest installation.
The fireproof pipe insulation can be used for heating and domestic water systems, pipe, air conditioning, and ventilation lines, and solar lines.
Please observe the installation guidelines!
Material: Rock wool insulation shell with surface coating of grid-reinforced aluminum foil
Over time, there is no change in the fire behavior of mineral wool.
Over time, there is no change in the thermal conductivity of mineral wool.
Length: 1 meter
Fire classification: A2Ls1d0 (EN 13501-1)
Color: silver
Thermal conductivity:
< 40 mm:
0.034 W/mK at 10°C
0.037 W/mK at 40°C
0.055 W/mK at 150°C
> 40 mm:
0.035 W/mK at 10°C
0.038 W/mK at 40°C
0.055 W/mK at 150°C
Fire behavior:
A2L s1 d0 (non-combustible)
Temperature range:
up to 0°C to +250°C
Melting temperature >1000°C
Reference | A* | B* | Length | Box content |
15 - 20 | 15mm | 20mm | 1 m | 42 m |
18 - 20 | 18mm | 20mm | 1 m | 42 m |
22 - 20 | 22mm | 20mm | 1 m | 36 m |
28 - 20 | 28mm | 20mm | 1 m | 30 m |
35 - 20 | 35mm | 20mm | 1 m | 25 m |
42 - 20 | 42mm | 20mm | 1 m | 20 m |
48 - 20 | 48mm | 20mm | 1 m | 20 m |
60 - 20 | 60mm | 20mm | 1 m | 15 m |
* see photo
Cold water pipes DIN 1988 200 or without requirements
50% GEG
-Pipes and fittings in wall and ceiling penetrations, at pipe intersections,
at pipe connection points, at central pipe distributors
-Pipes in components, between heated rooms of different users.
100% GEG
-Pipes in unheated rooms and in basement rooms
-Pipes in exterior walls as well as in building structures between unheated rooms, in ducts and shafts
-Pipes for supplying multiple parties
-Hot water pipes
-Hot water pipes with a water content of up to 3 liters, which are neither included in the circulation circuit
nor equipped with electric trace heating (branch lines) and are located in heated rooms. (*)
*) Although no requirements are set here, insulation must be provided for the following reasons:
Corrosion protection, prevention of cracking and flow noises, air and structure-borne sound insulation, reduction of heat load.
To maintain user comfort, the hot water pipe should be insulated to prevent unnecessary cooling through components, etc.